![]() | Partition Wall Making - Course: Timberwork techniques. Instruction examples for practical vocational training (Institut für Berufliche Entwicklung, 35 p.) |
The pitch sizes for the partition wall shown in the detailed drawing are to be determined.
Known:
Room height: 2500 mm
Length of surface covering
material: 2500 mm
aadm = 600 mm
The runners are cut from 50 mm
thick and 4000 mm long boards
Figure
Hand tools
None
Measuring and testing means
None
Auxiliary accessories
Paper for calculations, pencil, possibly calculator
Necessary previous knowledge
Fundamental operations, reading of drawings
Sequence of operations |
Comments |
1. Determine the cross section of timbers for the posts. |
- Read cross section in table 1. |
2. Calculate the pitch size for wall (1). | |
Requ.: | |
Known: |
|
b = 60 mm |
Lt = 2300 mm |
|
|
G1 = 4600 mm |
nFa = 4 |
|
|
aadm = 600 mm |
nTa = 2 |
M1 = 2500 mm |
|
|
a1 = 567.5 mm |
|
( ) indicates the steps of calculation. |
3. Calculate the pitch size for wall (2) |
- Since the partition walls meet at right angles, G1 for wall
(2) is not 5000 mm! |
Requ.: | |
Known: |
- Follow steps of solution exactly! |
b = 60 mm | |
| |
G1 = 5000 mm - d |
|
| |
aadm = 600 mm | |
d = 80 mm |
(1) G1 = 5000 mm - 80 mm |
M1 = 2500 mm |
G1 = 4920 mm |
|
|
|
nTa = 2 |
|
|
|
|
|
nFa = 5! |
|
|
|
a2 = 486 mm |