7.1.3. Technical data

Several examples of technical data feature in Figures 116 and 117 and in Surveys 16 and 17.

Foot induction motors


Figure 116 - Dimensional images of a foot induction motor (e.g. 65/IM 1001)

(1) Length side, (2) Drive side
1 Axial pressure, 2 Stop socket Pg9, 3 Protective conductor, 4 Air entry, 5 Minimal distance

Survey 16 - Characteristic values of foot induction motors

Design/nominal size

Rated voltage (Ws)

Rated current

Power input

Power output

Speed

-

V

A

W

W

rpm

65/IM 1001

220

0.30

60

10

1400



0.42

80

16

2800

1)

220/380

0.38/0.22

70

16

1400



0.49/0.28

105

25

2800

75/IM 1001

220

0.52

100

25

1400



0.62

125

40

2800


220/380

0.59/0.34

110

40

1400

2)


0.73/0.42

160

60

2800

1) C = 2µF 2) C = 2.5µF

Flange induction motors


Figure 117 - Dimensional images of a flange induction motor (e.g. 75/IM 3601)

(1) Length side, (2) Drive side,
1 Air entry, 2 Screw-in depth max. 12 mm

Survey 17 - Characteristic values for flange induction motors

Design/nominal size

Rated voltage (Ws)

Rated current

Power input

Power output

Speed

-

V

A

W

W

rpm

65/IM 3601

220

0.38 1)

80

16

1400



0.50 2)

100

25

2800


220/380

0.42/0.24

75

25

1400



0.56/0.32

115

40

2800

75/IM 3601

220

0.58 3)

120

40

1400



0.74 4)

150

60

2800


220/380

0.70/0.40

150

60

1400



1.08/0.60

200

90

2800