![]() | Lighting Installation - Basic vocational knowledge (Institut für Berufliche Entwicklung, 164 p.) |
![]() | ![]() | (introduction...) |
![]() | ![]() | Preface |
![]() | ![]() | 1. General Remarks on Lighting Installations |
![]() | ![]() | 2. Elements |
![]() | ![]() | 2.1. Basic Terms in Lighting Engineering |
![]() | ![]() | 2.2. The Eye and its Visual Capacity |
![]() | ![]() | 2.3. Colour, Light and Space |
![]() | ![]() | 2.4. Quality Characteristics of Lighting |
![]() | ![]() | 2.4.1. Indoor Lighting |
![]() | ![]() | 2.4.2. Outdoor Lighting |
![]() | ![]() | 3. Calculation of Illuminance |
![]() | ![]() | (introduction...) |
![]() | ![]() | 3.1. Luminous Flux Method for Interior Space |
![]() | ![]() | 3.2. Luminous Intensity Method - for Rotation-Symmetrical Lighting Fittings |
![]() | ![]() | 4. Measurements at Lighting Installations |
![]() | ![]() | 4.1. General Remarks |
![]() | ![]() | 4.2. Illuminance Measuring |
![]() | ![]() | 4.3. Luminous Density Measuring |
![]() | ![]() | 5. Light Sources for Illuminating Purposes |
![]() | ![]() | 5.1. General Remarks |
![]() | ![]() | 5.2. Thermal Radiation Lamps |
![]() | ![]() | 5.2.1. Genera1-Service Lamps |
![]() | ![]() | 5.2.2. Shaped Lamps for Technical and Decorative Purposes, Tube Lamps |
![]() | ![]() | 5.2.3. Projection Lamps |
![]() | ![]() | 5.2.4. Halogen-Filled Incandescent Lamps |
![]() | ![]() | 5.3. Discharge Lamps |
![]() | ![]() | 5.3.1. Low-Pressure Lamps |
![]() | ![]() | (introduction...) |
![]() | ![]() | 5.3.1.1. Tubalar Fluorescent Lamps |
![]() | ![]() | 5.3.1.2. Sodium Vapour Lamps |
![]() | ![]() | 5.3.2. High-Pressure Lamps |
![]() | ![]() | (introduction...) |
![]() | ![]() | 5.3.2.1. Mercury-Vapour Lamps |
![]() | ![]() | 5.3.2.2. Halogen Metal Vapour Lamps |
![]() | ![]() | 5.3.2.3. Sodium Vapour Lamps |
![]() | ![]() | 6. Operating Components for Discharge Lamps |
![]() | ![]() | 6.1. Ballast |
![]() | ![]() | 6.2. Starter Switches |
![]() | ![]() | 6.3. Ignition Sets |
![]() | ![]() | 6.4. Compensating Capacitors |
![]() | ![]() | 6.5. Intensity Control of Lamps |
![]() | ![]() | 7. Comparative Tabulations of the Properties and Energy Consumption of Lamps |
![]() | ![]() | 8. Lighting Fittings |
![]() | ![]() | (introduction...) |
![]() | ![]() | 8.1. Protection Classes |
![]() | ![]() | 8.2. Degrees of Protection |
![]() | ![]() | 8.3. Efficiency of a Fitting |
![]() | ![]() | 8.4. Kinds of Lighting Fittings |
![]() | ![]() | (introduction...) |
![]() | ![]() | 8.4.1. Functional Lighting Fittings for Indoor Lighting |
![]() | ![]() | 8.4.1.1. General Lighting Fittings |
![]() | ![]() | 8.4.1.2. Local Lamps |
![]() | ![]() | 8.4.1.3. Flameproof and Explosion-proof Lighting Fittings |
![]() | ![]() | 8.4.2. Outdoor-Lighting Fittings |
![]() | ![]() | 8.4.2.1. Street Lighting Lanterns |
![]() | ![]() | 8.4.2.2. Decorative Outdoor-Lighting Fittings |
![]() | ![]() | 8.4.2.3. Floodlights and Spotlights |
![]() | ![]() | 8.4.3. Lighting Fittings for Representation Purposes and Housing Space |
![]() | ![]() | 8.4.4. Lighting Fittings for Special Purposes |
![]() | ![]() | 9. Commercial Lighting Fittings |
![]() | ![]() | (introduction...) |
![]() | ![]() | 9.1. Self-Luminous Lighting Installations |
![]() | ![]() | (introduction...) |
![]() | ![]() | 9.1.1. Cold-Cathode Tubes (High-Voltage Fluorescent Lamps) |
![]() | ![]() | 9.1.2. Operating Components |
![]() | ![]() | 9.2. Transilluminated Lighting Installations |
![]() | ![]() | 9.3. Illuminated Installations |
![]() | ![]() | (introduction...) |
![]() | ![]() | 9.3.1. Lighting Installations in Sales Rooms |
![]() | ![]() | 9.3.2. Shop-window Lighting |
![]() | ![]() | 10. Mounting of Lighting Installations |
![]() | ![]() | (introduction...) |
![]() | ![]() | 10.1. Mounting of Indoor-Lighting Installations |
![]() | ![]() | 10.2. Factory Lighting - an Example of Indoor-Lighting Installations |
![]() | ![]() | (introduction...) |
![]() | ![]() | 10.2.1. Metal Working Factories |
![]() | ![]() | 10.2.2. Textile Mills |
![]() | ![]() | 10.2.3. Agriculture |
![]() | ![]() | 10.2.4. Summary Hints for Practice |
![]() | ![]() | 10.3. Outdoor Lighting Installations Demonstrated by the Example of Industrial Building |
![]() | ![]() | (introduction...) |
![]() | ![]() | 10.3.1. Criteria for Quality Assessment of Outdoor Lighting Installations |
![]() | ![]() | 10.3.2. Production Areas |
![]() | ![]() | 10.3.3. Storage Areas |
![]() | ![]() | 10.3.4. Building Site Lighting |
![]() | ![]() | 10.3.5. Summary Hints for Practice |
![]() | ![]() | 11. Inspection and Repair of Lighting Installations |
![]() | ![]() | 11.1. General Remarks |
![]() | ![]() | 11.2. Depreciation Factors |
![]() | ![]() | 11.3. Time of Maintenance |
![]() | ![]() | 11.4. Carrying out of Maintenance |
![]() | ![]() | 11.5. Cleaning |
![]() | ![]() | 11.6. Auxiliary Means for Maintenance |
![]() | ![]() | 11.7. Hints for Practice |
![]() | ![]() | 12. Answers to the Questions for Repetition and Knowledge Tests |